82

Electrical Power-II EP-2 6th Semester Dec 2016 Diploma Paper. Download Previous year Electrical Power-II EP-2 6th Sem EE/EEE/5239/Diploma Solved Question Paper.

Electrical Power-II EP-2 6th Sem EEE Dec 2016 Diploma PSBTE Paper

ELECTRICAL POWER 2 EP-II 6TH SEM DIPLOMA PSBTE DEC 2016 PAPER      

Duration : 3 Hrs                                                                                      M.Marks : 75     

                           SECTION A

        1. Fill in the blanks :

     1. In a balanced 3 phase system, the sum of the three 3 phase emfs is equal to …..
     2. When switch is opened _____ is produced.
     3. VCB stands for Vacuum Circuit Breaker .
     4. A lightening arrestor is always connected between the Line and Earth .
     5. Block rate tariff is usually applicable to consumers.
     6. Fusing current is _____ than current carrying capacity of a fuse.
     7. The basic purpose of earthing is to Protect the risk of electric shocks .
     8. Ground wire is used to protect transmission line against……….
     9. Earth relays have ____ current ratings.
   10. The most important stator winding fault of an alternator is fault.

                                                                        SECTION-B
Q2. Attempt any five questions.                                                 5×6=30

    a) What are the requirements of a good lightening arrestor?
    b) The maximum demand of a power plant is 100 MW. The capacity factor is 0.5 and utilization factor is 0.9.find load factor, plant capacity and annual energy                    generated.
    c) What do you mean by power factor? Explain the necessity of improving power factor.
    d) What do you understand by switchgear? What is its function?
    e) What are symmetrical and unsymmetrical faults?
    f) What do you mean by economics of generation? What are the governing factors?
    g) Explain an ELCB. Where it is used?
    h) Why is earth wire placed above the overhead lines and what is the use of ground wire?

                        SECTION-C

     Q3. Attempt any three questions.                                                                                     3×10=30

    1. Explain the principle and working of a Buchholz relay. Where is it used and why?
    2. Give the protection scheme of a transformer.
    3. Give function, classification and characteristics of various fuses.
    4. Explain comparison between various types of power stations.
    5. (a) Give reason, how higher diversity factor can be obtained? Also mention the need of diversity factor
        (b) A generation station has a overall efficiency of 25% and 0.75 kg of coal is burnt per kWh at the station. Determine the calorific value of coal in kilocalories                      per kg.
   6. Write short note on
      (a) Sulphur Hexa fluoride circuit breakers
      (b) Vacuum circuit breaker

Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma PSBTE Paper


Get Started

Section a FILL IN THE BLANKS Electrical Power-II DEC 2016 paper

In a balanced 3 phase system, the sum of the three 3 phase emfs is equal to ______

In a balanced 3 phase system, the sum of the three 3 phase emfs is equal to …..
   

When switch is opened _______ is produced.

When switch is opened….is produced.
    

VCB stands for _____________

VCB stands for…..
    

A lightening arrestor is always connected between ……. and……..

A lightening arrestor is always connected between ……. and……..
     

Block rate tariff is usually applicable to consumers

Block rate tariff is usually applicable to consumers.
   

Fusing current is than current carrying capacity of a fuse.

Fusing current is than current carrying capacity of a fuse.
  

The basic purpose of earthing is __________

The basic purpose of earthing is……..
   

Ground wire is used to protect transmission line against ________

Ground wire is used to protect transmission line against……….
    

Earth relays have current ratings.

Earth relays have current ratings.
  

The most important stator winding fault of an alternator is fault.

 The most important stator winding fault of an alternator is fault.

Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma PSBTE Paper Click Here

Section B :Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma Paper

What are the requirements of a good lightening arrestor?

Requirements of a good lightening arrestor

The maximum demand of a power plant is 100 MW. The capacity factor is 0.5 and utilization factor is 0.9.find load factor, plant capacity and annual energy generated.

maximum demand of a power plant is 100 MW. The capacity factor is 0.5 and utilization factor is 0.9.find load factor, plant capacity and annual energy generated.

What do you mean by power factor? Explain the necessity of improving power factor.

Power factor and  necessity of improving power factor.

What do you understand by switchgear? What is its function?

switchgearits function

What are symmetrical and unsymmetrical faults?

Symmetrical and unsymmetrical faults

What do you mean by economics of generation? What are the governing factors?

Economics of generationand governing factors

Explain an ELCB. Where it is used?

ELCB. Where it is used

Why is earth wire placed above the overhead lines and what is the use of ground wire?

Why is earth wire placed above the overhead lines 

 Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma Paper Click Here

 Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma Paper


Get Started

https://www.youtube.com/watch?v=UHX6f8TIvX8https://www.youtube.com/watch?v=M_RR6LVICp0https://www.youtube.com/watch?v=mV41CMWonN4https://www.youtube.com/watch?v=s0LVPE0Q3LE&list=PLA9Q9SDZ781WXNAWit379A4CRLMvjGiUw&index=14&t=0s

Section c Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma Paper

Explain the principle and working of a Buchholz relay. Where is it used and why?

Principle and working of a Buchholz relay. Where is it used

Give the protection scheme of a transformer.

Protection scheme of a transformer.

Give function, classification and characteristics of various fuses.

Classification and characteristics of various fuses

Explain comparison between various types of power stations.

Comparison between various types of power stations

Give reason, how higher diversity factor can be obtained? Also mention the need of diversity factor

A generation station has a overall efficiency of 25% and 0.75 kg of coal is burnt per kWh at the station. Determine the calorific value of coal in kilocalories per kg.

A generation station has a overall efficiency of 25% and 0.75 kg of coal is burnt per kWh at the station. Determine the calorific value of coal in kilocalories per kg.

6. Write short note on (a) Sulphur Hexa fluoride circuit

(a) Sulphur Hexa fluoride circuit breakers

(b) Vacuum circuit breaker

(b) Vacuum circuit breaker

 Electrical Power-II EP-2 6th Sem EEE DEC 2016 Diploma Paper Contact Us